x
A l o f t   m e d t e c h
logo
  • Aloft MedTech R7-103, M3M URBANA, Sector 67, Gurugram, Haryana, 122101
  • Mon - Sat(9.30 - 6.00) Sunday - Closed

Category:

Description

HUBT-20P – 14C Urea Breath Analyzer

Product Overview

The HUBT-20P Urea Breath Analyzer is a professional diagnostic device designed for rapid, non-invasive detection of Helicobacter pylori (H. pylori) infection. It works in combination with 14C-urea capsules and test collection cards, providing accurate and reliable results within minutes. Manufactured by Shenzhen Zhonghe Headway Bio-Sci & Tech Co., Ltd., this analyzer is widely used in hospitals, laboratories, and gastroenterology clinics across more than 16 countries.


About the Manufacturer

Headway Bio-Sci & Tech Co., Ltd. was founded in 1996 in Shenzhen, China.
It is a global leader in 13C & 14C urea breath test systems with:

  • 3 R&D centers and 3 manufacturing facilities

  • 70,000 m² production area

  • Operations across 16 countries and regions

  • Over 20,000 medical institutions served

  • More than 300 million people benefited

Vision: Make the pursuit of health easy
Mission: To be the leader in global breath detection industry
Core Values: Innovation, Practicality, Responsibility, Cooperation


What is Helicobacter pylori?

Helicobacter pylori (H. pylori) is a Gram-negative, microaerophilic bacterium that colonizes the stomach lining.
It is a leading cause of:

  • Chronic active gastritis

  • Peptic ulcer disease

  • Gastric carcinoma

  • Gastric MALT lymphoma

According to the World Health Organization, H. pylori is a Class I carcinogen and affects nearly 50% of the global population.


Why Choose the Urea Breath Test (UBT)?

The UBT is the gold-standard method for diagnosing active H. pylori infection and for monitoring post-treatment eradication.
Compared to traditional invasive methods (endoscopy, biopsy), it is:

  • Non-invasive

  • Safe

  • Simple

  • Highly accurate

  • Fast (results in minutes)


Operating Principle

When a patient ingests a small 14C-urea capsule, if H. pylori bacteria are present, their urease enzyme breaks the urea into ammonia and labeled carbon dioxide (14CO₂).
The patient’s exhaled breath is then analyzed by the HUBT-20P system to detect the presence of 14CO₂ — confirming the infection.


Testing Procedure

  1. The patient takes one 14C-urea capsule orally.

  2. Wait for approximately 15 minutes.

  3. The patient exhales onto a HUBT-20P collection card until the color changes from orange to yellow.

  4. The analyzer processes the sample and displays results as positive or negative for H. pylori infection.


Safety & Regulatory Compliance

  • Each test exposes patients to only 1.59 μSv, significantly less than a one-hour airplane flight (3.00 μSv).

  • The test is safe and environment-friendly.

  • China’s Ministry of Environmental Protection and the U.S. Nuclear Regulatory Commission (NRC) have both granted regulatory exemption for medical diagnostic use of 14C-urea capsules.

  • Over 10 million tests have been safely conducted worldwide.


Product Highlights

  • High accuracy with CPM (Counts Per Minute) results

  • Lightweight and compact design (only 9 kg)

  • User-friendly interface and fast operation

  • On-site analysis available within 4 minutes 10 seconds

  • Automatic measurement and data storage

  • PC connectivity and professional software integration


Technical Specifications

Physical Specifications:

  • Dimensions: 320 × 300 × 280 mm

  • Weight: 9 kg

Performance:

  • Detection efficiency (14C unquenched standard): ≥ 15%

  • Background count: ≤ 50 CPM

  • Stability: ≤ 30% variation after 48 hours continuous operation

Power Supply:

  • 110–240V AC, 50/60Hz, 30VA max

Operating Conditions:

  • Temperature: 5°C – 40°C

  • Relative Humidity: ≤ 75%

  • Atmospheric Pressure: 75–106 kPa

  • Preheating Time: ≥ 30 minutes

Storage Conditions:

  • Temperature: -10°C – +55°C

  • Relative Humidity: ≤ 75%

  • Store in a ventilated area, free from corrosive gases


Applications

The HUBT-20P is ideal for:

  • Hospitals and clinics

  • Gastroenterology departments

  • Diagnostic laboratories

  • Post-treatment monitoring for H. pylori eradication

Reviews

There are no reviews yet.

Be the first to review “HUBT-20P – 14C Urea Breath Analyzer”

Your email address will not be published. Required fields are marked *