HUBT-20P – 14C Urea Breath Analyzer
Product Overview
The HUBT-20P Urea Breath Analyzer is a professional diagnostic device designed for rapid, non-invasive detection of Helicobacter pylori (H. pylori) infection. It works in combination with 14C-urea capsules and test collection cards, providing accurate and reliable results within minutes. Manufactured by Shenzhen Zhonghe Headway Bio-Sci & Tech Co., Ltd., this analyzer is widely used in hospitals, laboratories, and gastroenterology clinics across more than 16 countries.
About the Manufacturer
Headway Bio-Sci & Tech Co., Ltd. was founded in 1996 in Shenzhen, China.
It is a global leader in 13C & 14C urea breath test systems with:
-
3 R&D centers and 3 manufacturing facilities
-
70,000 m² production area
-
Operations across 16 countries and regions
-
Over 20,000 medical institutions served
-
More than 300 million people benefited
Vision: Make the pursuit of health easy
Mission: To be the leader in global breath detection industry
Core Values: Innovation, Practicality, Responsibility, Cooperation
What is Helicobacter pylori?
Helicobacter pylori (H. pylori) is a Gram-negative, microaerophilic bacterium that colonizes the stomach lining.
It is a leading cause of:
-
Chronic active gastritis
-
Peptic ulcer disease
-
Gastric carcinoma
-
Gastric MALT lymphoma
According to the World Health Organization, H. pylori is a Class I carcinogen and affects nearly 50% of the global population.
Why Choose the Urea Breath Test (UBT)?
The UBT is the gold-standard method for diagnosing active H. pylori infection and for monitoring post-treatment eradication.
Compared to traditional invasive methods (endoscopy, biopsy), it is:
-
Non-invasive
-
Safe
-
Simple
-
Highly accurate
-
Fast (results in minutes)
Operating Principle
When a patient ingests a small 14C-urea capsule, if H. pylori bacteria are present, their urease enzyme breaks the urea into ammonia and labeled carbon dioxide (14CO₂).
The patient’s exhaled breath is then analyzed by the HUBT-20P system to detect the presence of 14CO₂ — confirming the infection.
Testing Procedure
-
The patient takes one 14C-urea capsule orally.
-
Wait for approximately 15 minutes.
-
The patient exhales onto a HUBT-20P collection card until the color changes from orange to yellow.
-
The analyzer processes the sample and displays results as positive or negative for H. pylori infection.
Safety & Regulatory Compliance
-
Each test exposes patients to only 1.59 μSv, significantly less than a one-hour airplane flight (3.00 μSv).
-
The test is safe and environment-friendly.
-
China’s Ministry of Environmental Protection and the U.S. Nuclear Regulatory Commission (NRC) have both granted regulatory exemption for medical diagnostic use of 14C-urea capsules.
-
Over 10 million tests have been safely conducted worldwide.
Product Highlights
-
High accuracy with CPM (Counts Per Minute) results
-
Lightweight and compact design (only 9 kg)
-
User-friendly interface and fast operation
-
On-site analysis available within 4 minutes 10 seconds
-
Automatic measurement and data storage
-
PC connectivity and professional software integration
Technical Specifications
Physical Specifications:
-
Dimensions: 320 × 300 × 280 mm
-
Weight: 9 kg
Performance:
-
Detection efficiency (14C unquenched standard): ≥ 15%
-
Background count: ≤ 50 CPM
-
Stability: ≤ 30% variation after 48 hours continuous operation
Power Supply:
-
110–240V AC, 50/60Hz, 30VA max
Operating Conditions:
-
Temperature: 5°C – 40°C
-
Relative Humidity: ≤ 75%
-
Atmospheric Pressure: 75–106 kPa
-
Preheating Time: ≥ 30 minutes
Storage Conditions:
-
Temperature: -10°C – +55°C
-
Relative Humidity: ≤ 75%
-
Store in a ventilated area, free from corrosive gases
Applications
The HUBT-20P is ideal for:
-
Hospitals and clinics
-
Gastroenterology departments
-
Diagnostic laboratories
-
Post-treatment monitoring for H. pylori eradication